ViBRA AJ Series Precision Balance

Common Specification

Tare : Zero to Full weighing range
Span adjustment : AJ・・・・・Manual operation Span Adjustment with external calibration weight
AJH・・・・・Semi-automatic Span Adjustment with built-in calibration weight
Over error : “o-Err” showed when Full weight range + 9 more digits over
Temperature and
humidity range
: 5 ~ 35℃ (E type), 10~30℃ (CE type) Up to 80% rh(without the dew condensation)
Power source : AC adapter Input 100-240VAC / Output 12VDC
Output : RS232C(Din5p)

Features

  • Simple but profound
  • Vast potential in the compact housing
  • For laboratory, factory, jewelry shops, etc…
  • Quick response and stable indication
  • OIML and EU class 2, class 1 approved

Specification

Model name AJ-220CEN AJ-320CEN AJ-420CEN AJ-620CEN AJ-820CEN AJ-1200CEN
Capacity 220g 320g 420g 620g 820g 1200g
Readability (d) 0.001g 0.001g 0.001g 0.001g 0.01g 0.01g
Verification intervals (e) 0.01g 0.01g 0.01g 0.01g 0.01g 0.1g
Accuracy class
Repeatability 0.001g 0.001g 0.001g 0.001g 0.01g 0.01g
Linearity ±0.001g ±0.001g ±0.001g ±0.002g ±0.01g ±0.01g
Stabilization time 2.5 sec. 2.5 sec. 2.0 sec. 2.0 sec. 2.0 sec. 2.0 sec.
Pan size 118mm dia 170×142mm
Dimensions(WDH) 182×235×168mm(Including Windshield) 182×235×75mm
Windshield × ×

 

Model name AJ-2200CEN AJ-3200CEN AJ-4200CEN AJ-6200CEN AJ-8200CEN AJ-12KCEN
Capacity 2200g 3200g 4200g 6200g 8200g 12000g
Readability (d) 0.01g 0.01g 0.01g 0.01g 0.1g 0.1g
Verification intervals (e) 0.1g 0.1g 0.1g 0.1g 1g 1g
Accuracy class
Repeatability 0.01g 0.01g 0.01g 0.01g 0.1g 0.1g
Linearity ±0.01g ±0.01g ±0.01g ±0.02g ±0.1g ±0.1g
Stabilization time 2.5 sec. 2.5 sec. 2.5 sec. 3.0 sec. 2.5 sec. 2.5 sec.
Pan size 180×160mm
Dimensions(WDH) 192×265×87mm
Windshield × × × × × ×

ViBRA ALE Series Precision Balance

ViBRA ALE Series Precision Balance

Common Specification

Tare : Zero to Full weighing range
Span adjustment : ALE・・・・・Manual operation Span Adjustment with external calibration weight
ALE-R・・・・・Semi-automatic Span Adjustment with built-in calibration weight
Over error : “o-Err” showed when Full weight range + 9 more digits over
Temperature and
humidity range
: 10~ 30℃、Up to 85% rh(without the dew condensation)
Power source : AC adapter: Input 100-240VAC,50-60Hz / Output 5.95VDC
Dry-cell battery: AA batteries 4 pcs
Output : RS232C + USB

Precision Balance Features

  • Compact housing
  • Short stabilization time
  • User friendly operation
  • ALE provides three advantages as key values. ALE series is new answer to optimized weighing operation in the laboratory.

Precision Balance Specification

Internal weight models

Model name ALE223R ALE323R ALE623R
Capacity 220g 320g 620g
Readability (d) 0.001g 0.001g 0.001g
Verification intervals (e) 0.01g 0.01g 0.01g
Accuracy class
Repeatability 0.001g 0.001g 0.001g
Stabilization time 1.6sec. 1.6sec. 1.6sec.
Pan size 118mm dia.
Dimensions (WDH) 205x270x301mm (incl. windshield)
Windshield Incl. as standard

– – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –

Model name ALE1502R ALE2202R ALE3202R ALE6202R
Capacity 1500g 2200g 3200g 6200g
Readability (d) 0.01g 0.01g 0.01g 0.01g
Verification intervals (e) 0.1g 0.1g 0.1g 0.1g
Accuracy class
Repeatability 0.01g 0.01g 0.01g 0.01g
Stabilization time 1.6sec. 1.6sec. 1.6sec. 1.6sec.
Pan size 180×160 mm
Dimensions (WDH) 192x265x86 mm
Windshield N/A

– – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –

Model name ALE6201R ALE8201R ALE15001R
Capacity 6200g 8200g 15000g
Readability (d) 0.1g 0.1g 0.1g
Verification intervals (e) 1g 1g 1g
Accuracy class
Repeatability 0.01g 0.1g 0.1g
Stabilization time 1.6sec. 1.6sec. 1.6sec.
Pan size 180×160 mm
Dimensions (WDH) 192x265x86 mm
Windshield N/A

 

External weight models

Model name ALE223 ALE323 ALE623
Capacity 220g 320g 620g
Readability (d) 0.001g 0.001g 0.001g
Verification intervals (e) 0.01g 0.01g 0.01g
Accuracy class
Repeatability 0.001g 0.001g 0.001g
Stabilization time 1.6sec. 1.6sec. 1.6sec.
Pan size 118mm dia.
Dimensions (WDH) 205x270x301mm (incl. windshield)
Windshield Incl. as standard

– – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –

Model name ALE1502 ALE2202 ALE3202 ALE6202
Capacity 1500g 2200g 3200g 6200g
Readability (d) 0.01g 0.01g 0.01g 0.01g
Verification intervals (e) 0.1g 0.1g 0.1g 0.1g
Accuracy class
Repeatability 0.01g 0.01g 0.01g 0.01g
Stabilization time 1.6sec. 1.6sec. 1.6sec. 1.6sec.
Pan size 180×160 mm
Dimensions (WDH) 192x265x86 mm
Windshield N/A

– – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –

Model name ALE8201 ALE15001
Capacity 8200g 15000g
Readability (d) 0.1g 0.1g
Verification intervals (e) 1g 1g
Accuracy class
Repeatability 0.1g 0.1g
Stabilization time 1.6sec. 1.6sec.
Pan size 180×160 mm
Dimensions (WDH) 192x265x86 mm
Windshield N/A

ViBRA CJ Series Precision Balance

ViBRA CJ Series Precision Balance

Common Specification

Tare : Zero to Full weighing range
Span adjustment : Manual operation Span Adjustment with external calibration weight
Ingress Protection Rating : IP65
Over error : “o-Err” showed when Full weight range + 9 more digits over
Temperature and
humidity range
: 0 ~ 40℃、Up to 80% rh(without the dew condensation)
Power source : AC adapter Input 100-240VAC / Output 5.95VDC
Output : RS232C(D ‘sub 9P)

Features

ViBRA CJ Series Precision Balance :

  • IP65, water and dust proof
  • Reliable measurement even in tough condition

Specification

Model name CJ-820E
Capacity 820g
Readability (d) 0.01g
Repeatability 0.01g
Linearity ±0.01g
Pan size 140mm dia
Dimensions(WDH) 206×312×89mm

 

Model name CJ-3200E CJ-8200E CJ-15KE
Capacity 3200g 8200g 15000g
Readability (d) 0.1g 0.1g 1g
Repeatability 0.1g 0.1g 1g
Linearity ±0.1g ±0.1g ±1g
Pan size 190×190mm
Dimensions(WDH) 206×312×89mm

สินค้า Vibra

ขอใบเสนอราคา     ติดต่อเรา

ViBRA CUX Series Precision Balance

Precision Balance Common Specification

Tare : Zero to full weighing range
Maximum counting quantity : 600,000pcs for CUX60~12K, 16KS, 30KS
100,000pcs for CUX16K, 30K, 60K, 150K
Span adjustment : Manual span adjustment with external weight
Over error : “o-Err” appears when load of full weight range + 9 digits over
Temperature and
humidity range
: 0~ 40℃、Up to 80% rh (without the dew condensation)
Power source : Dedicated AC adapter
Output : RS232C (D-sub 9P)

Precision Balance Features

  • ACR (Automatic Counting Revision) function for accurate counting operation
  • Three back-lit LCD display to indicate “quantity”, “unit weight” and total weight at the same time
  • Tare-reminder function

Specification

Model name CUX60 CUX150 CUX300 CUX600 CUX1500
Measurement system Tuning-fork sensor
Capacity 60g 150g 300g 600g 1500g
Countable unit weight 0.1mg 0.25mg 0.5mg 1mg 2.5mg
Minimum readability 0.001g 0.002g 0.005g 0.01g 0.05g
Pan size 118mm dia. 140mm dia. 234x204mm
Dimension (W x D x H) 260x344x173mm (including windshield) 260x344x101mm

 

Model name CUX3000 CUX6000 CUX12K CUX16KS CUX30KS
Measurement system Tuning-fork sensor
Capacity 3000g 6000g 12kg 16kg 30kg
Countable unit weight 5mg 10mg 20mg 50mg 0.1g
Minimum readability 0.05g 0.1g 1g 0.5g 1g
Pan size 234x204mm 360x320mm
Dimension (W x D x H) 260x344x101mm 360x482x683mm

 

Model name CUX16K CUX30K CUX60K CUX150K
Measurement system strain gauge load cell sensor
Capacity 16kg 30kg 60kg 150kg
Countable unit weight 0.16g 0.3g 0.6g 1.5g
Minimum readability 0.002kg 0.005kg 0.01kg 0.02kg
Pan size 330x310mm 380x530mm
Dimension (W x D x H) 330x448x491mm 380x669x766mm

ViBRA FS Series Platform Scale

Common Specification Platform Scale

Tare : Zero to Full weighing range
Span adjustment : Manual operation Span Adjustment with external calibration weight
Ingress Protection Rating : IP65
Over error : “o-Err” showed when Full weight range + 9 more digits over
Temperature and
humidity range
: 5 ~ 40℃、Up to 85% rh (without the dew condensation)
Power source : AC adapter Input 100-240VAC / Output 6VDC and dry-cell battery *1
Output : RS232C(D’ sub 9Pin)+Printer out put(Din 8Pin)
Scale cable length : 5m for FS 150K1GF and 300K1GF.1m for all other models. *2

Features

  • High precision weighing in manufacturing process
  • Wide weighing range from 620g up to 300kg
  • IP65 water and dust proof
  • Dry-cell battery drive as standard feature
  • OIML and EU class2 approved

Specification Platform Scale

Model name FS623 FS3202 FS6202 FS15001
Capacity 620g 3200g 6200g 15000g
Readability (d) 0.001g 0.01g 0.01g 0.1g
Verification intervals (e) 0.01g 0.1g 0.1g 1g
Repeatability 0.001g 0.01g 0.01g 0.1g
Linearity ±0.002g ±0.02g ±0.02g ±0.2g
Stabilization time 3.0 sec. 3.0 sec. 3.0 sec. 3.0 sec.
Pan size 140mm dia 190 x 190mm 190 x 190mm 190 x 190mm
Dimensions(WDH) 294 x 352 x 570mm

 

Model name FS30K0.1G FS60K0.1G FS100K1G FS200K1G
Capacity 30kg 60kg 100kg 200kg
Readability (d) 0.1g 0.1g 1g 1g
Verification intervals (e) 1g 1g 10g 10g
Repeatability 0.1g 0.1g 1g 1g
Linearity ±0.1g ±0.2g ±2g ±2g
Stabilization time 3.0 sec. 2.5 sec. 2.5 sec. 2.0 sec.
Pan size 310 x 330mm 380 x 530mm 380 x 530mm 380 x 530mm
Dimensions(WDH) 310 x 444 x 672mm 380 x 653 x 804mm

 

Model name FS150K1GF FS300K1GF
Capacity 150kg 300kg
Readability (d) 1g 1g
Verification intervals (e) 10g 10g
Repeatability 0.7g 0.8g
Linearity ±3g ±5g
Stabilization time 2.0 sec. 2.0 sec.
Pan size 800 x 600mm 800 x 600mm
Dimensions(WDH) 800 x 600 x x142mm

ViBRA FZ Series Anti-Explosion Electronic Scale

Common Specification Electronic Scale

Tare : Zero to Full weighing range
Span adjustment : Manual operation Span Adjustment with external calibration weight
ATEX approval : Ⅱ 1 G Ex ia Ⅱ B T4 Ga
Ingress Protection Rating : IP65
OIML & EC approval : classⅡ
Over error : “o-Err” showed when Full weight range + 9 more digits over
Temperature and
humidity range
: 5~ 40℃ (Scale & display), 0~40℃ (Power suppy box), Up to 85%
rh(without the dew condensation)
Power source : Power supply box attached as standard
Output : RS232C or option connector
Indicator : i02 or i03 selectable *2
model name with i02: FZ 623Ex-i02
model name with i03: FZ 623Ex-i03
Scale cable length : 5m for FZ 150K1GFEx and 300K1GFEx.
1m for all other models. *3
Power supply cable : 5m. *4

Electronic Scale Features

  • Precision weighing in explosive gas area, category 1G (zone 0, 1 and 2)
  • Wide weighing range from 620g up to 300kg.
  • IP65 water and dust proof

Specification

Model name FZ623Ex FZ3202Ex FZ6202Ex FZ15001Ex
Capacity 620g 3200g 6200g 15000g
Readability (d) 0.001g 0.01g 0.01g 0.1g
Verification intervals (e) 0.01g 0.1g 0.1g 1g
Repeatability 0.001g 0.01g 0.01g 0.1g
Linearity ±0.002g ±0.02g ±0.02g ±0.2g
Stabilization time 3.0 sec. 3.0 sec. 3.0 sec. 3.0 sec.
Pan size 140mm dia 190 x 190mm 190 x 190mm 190 x 190mm
Dimensions(WDH) 294 x 352 x 570mm

 

Model name FZ30K0.1GEx FZ60K0.1GEx FZ100K1GEx FZ200K1GEx
Capacity 30kg 60kg 100kg 200kg
Readability (d) 0.1g 0.1g 1g 1g
Verification intervals (e) 1g 1g 10g 10g
Repeatability 0.1g 0.1g 1g 1g
Linearity ±0.1g ±0.2g ±2g ±2g
Stabilization time 3.0 sec. 2.5 sec. 2.5 sec. 2.0 sec.
Pan size 310 x 330mm 380 x 530mm 380 x 530mm 380 x 530mm
Dimensions(WDH) 310 x 444 x 672mm 380 x 653 x 804mm

 

Model name FZ150K1GFEx FZ300K1GFEx
Capacity 150kg 300kg
Readability (d) 1g 1g
Verification intervals (e) 10g 10g
Repeatability 0.7g 0.8g
Linearity ±3g ±5g
Stabilization time 2.0 sec. 2.0 sec.
Pan size 800 x 600mm 800 x 600mm
Dimensions(WDH) 800 x 600 x x142mm

ViBRA HJK Series Platform Scale

ViBRA HJK Series Platform Scale

Common Specification

Tare : Zero to Full weighing range
Span adjustment : HJK・・・・・With external calibration weight
HJK-R・・・・・Automatic with internal calibration weight
Ingress Protection Rating : IP65
Over error : “o-Err” showed when Full weight range + 9 more digits over
Temperature and
humidity range
: 5 ~ 35℃、Up to 80% rh(without the dew condensation)
Power source : Dedicated AC adapter (100-240 VAC, 12 VDC)
Output : RS232C (Dsub 9P)

Features

ViBRA HJK Series Platform Scale :

  • For more efficient precision weighing in manufacturing process
  • IP65 water&dust proof
  • High precision & durable

Specification

External weight types

Model name HJ17K0.1S HJ22K0.1S HJ33K0.1S HJ62K0.1DS
Capacity 17kg 22kg 33kg 6200g 62kg
Readability (d) 0.1g 0.1g 0.1g 0.1g 1g
Verification intervals (e) 1g 1g 1g 1g
Non-linearity ±0.3g ±0.3g ±0.3g ±0.3g ±3g
Repeatability (σ) 0.1g 0.1g 0.1g 0.1g 1g
Pan size 400 x 350 mm
Dimension (LDH) 350 x 482 x 175mm (350 x 482 x 700mm when pole option installed)
Calibration With external weight

Internal weight types

Model name HJ17K0.1SR HJ22K0.1SR HJ33K0.1SR HJ62K0.1DSR
Capacity 17kg 22kg 33kg 6200g 62kg
Readability (d) 0.1g 0.1g 0.1g 0.1g 1g
Verification intervals (e) 1g 1g 1g 1g
Non-linearity ±0.3g ±0.3g ±0.3g ±0.3g ±3g
Repeatability (σ) 0.1g 0.1g 0.1g 0.1g 1g
Pan size 400 x 350 mm
Dimension (LDH) 350 x 482 x 175mm (350 x 482 x 700mm when pole option installed)
Calibration With internal and external weight

 

สินค้า Vibra

ขอใบเสนอราคา     ติดต่อเรา

ViBRA HT Series Analytical Balance

Common Specification

Tare : Zero to full weighing range
Span adjustment : Internal weight models・・・・・Automatic and semi-automatic span adjustment with built-in weight
external weight models・・・・・Semi-automatic span adjustment with external weight
Over error : “o-Err” appears when load of full weight range + 90 digits over
Temperature and
humidity range
: 10~ 30℃、Up to 80% rh (without the dew condensation)
Power source : Dedicated AC adapter Input 100-240VAC / Output 12VDC
Output : RS232C & peripheral device output

Features

  • Tuning-fork Sensor Inside, New Concept of Analytical Balance
  • Best Usability
  • Resistant to disturbing vibration
  • Strong security control
  • Short stabilization time
  • Easy to clean

Specification

Model name HT84RCEN HT124RCEN HT224RCEN HT84CEN HT124CEN HT224CEN
Capacity 80g 120g 220g 80g 120g 220g
Readability (d) 0.1mg 0.1mg 0.1mg 0.1mg 0.1mg 0.1mg
Verification intervals (e) 1mg 1mg 1mg 1mg 1mg 1mg
Built-in weight N/A N/A N/A
Repeatability (σ) 0.05mg 0.05mg 0.05mg 0.05mg 0.05mg 0.05mg
Stabilization time 3.0 sec. 3.0 sec. 3.0 sec. 3.0 sec. 3.0 sec. 3.0 sec.
Pan size 80mm dia.
Dimensions 213×290×314mm (including windshield)

ViBRA LF Series Analytical Balance

ViBRA LF Series Analytical Balance

Common Specification

Tare : Zero to Full weighing range
Span adjustment : LF-R・・・・・ Automatic and semi-automatic Span Adjustment with built-in calibration weight
LF・・・・・Manual operation Span Adjustment with external calibration weight
Over error : “o-Err” showed when Full weight range + 9 more digits over
Temperature and
humidity range
: 10~ 30℃、Up to 80% rh (without the dew condensation)
Power source : AC adapter Input 100-240VAC / Output 5.95VDC
Output : RS232C output (D-sub 9pin)
USB output

Features

  • Automatic Span Adjustment Function to keep maintain high accuracy.
    Advice CAL function to notify proper calibration timing.
  • Combination Door which opens to left/right/double door
  • Windshield designed for wide and space saving
  • Large and eye-friendly display unit with back-light
  • Able to use as Counting Scale
  • Standard equipped USB Output

Specification

Model name LF225DR LF224R
Capacity 92g 220g 220g
Readability (d) 0.01mg 0.1mg 0.1mg
Verification intervals (e)
Repeatability 0.02mg 0.1mg 0.1mg
Linearity ±0.03mg ±0.2mg ±0.2mg
Stabilization time 5.0 sec. 3.0 sec. 3.0 sec.
Pan size 80mm dia
Dimensions(WDH) 210×320×335mm (Including Windshield)

ViBRA SJ Series Precision Balance

Common Specification

Tare : Zero to Full weighing range
Span adjustment : Manual operation Span Adjustment with external calibration weight
Over error : “o-Err” showed when Full weight range + 9 more digits over
Temperature and
humidity range
: 5 ~ 35℃ (E type) & 10~30℃ (CE type), Up to 80% rh(without the dew condensation)
Power source : AC adapter Input 100-240VAC / Output 12VDC
Output : Nil

Features

  • Highly usable basic applications
  • Short stabilization time and stable indication
  • Portability

Specification

Model name SJ-220CEN SJ-420CEN SJ-620CEN SJ-1200CEN
Capacity 220g 420g 620g 1200g
Readability (d) 0.01g 0.01g 0.01g 0.1g
Verification intervals (e) 0.01g 0.01g 0.1g 0.1g
Accuracy class
Repeatability 0.01g 0.01g 0.1g 0.1g
Linearity ±0.01g ±0.01g ±0.01g ±0.1g
Stabilization time 2.5 sec. 2.0 sec. 2.0 sec. 2.0 sec.
Pan size 140mm dia 170x140mm
Dimensions(WDH) 182×235×75mm

 

Model name SJ-2200CEN SJ-4200CEN SJ-6200CEN SJ-12KCEN
Capacity 2200g 4200g 6200g 12000g
Readability (d) 0.1g 0.1g 0.1g 1g
Verification intervals (e) 0.1g 0.1g 1g 1g
Accuracy class
Repeatability 0.1g 0.1g 1g 1g
Linearity ±0.1g ±0.1g ±0.1g ±1g
Stabilization time 2.5 sec. 2.5 sec. 3.0 sec. 2.5 sec.
Pan size 180×160mm
Dimensions(WDH) 192×265×87mm

การคำนวณค่า Measurement Uncertainty(MU)สำหรับการวัด ทดสอบ สอบเทียบ

Measurement Uncertainty(MU) เป็นข้อมูลผลการวัดที่มีความสำคัญโดยเฉพาะอย่างยิ่งในกรณีที่จะนำผลการวัดไปประกอบการตัดสินคุณภาพสินค้าตามมาตรฐานสากล เช่น ISO 9001, IATF 16949 และ ISO/IEC 17025 เป็นต้น เพื่อลดความเสี่ยงในการตัดสินผิด แต่เนื่องจาก MU มีรายละเอียดที่ต้องทำความเข้าใจมากจึงเป็นอุปสรรคสำหรับผู้ที่จะนำ MU มาประกอบการปฏิบัติงาน หลักสูตรนี้จะกล่าวถึงหลักการ ขั้นตอน และรายละเอียดของการคำนวณค่า Measurement Uncertainty(MU) ตามมาตรฐาน ISO/IEC Guide 98-3 ซึ่งเป็นมาตรฐานที่ยอมรับใช้ในระดับสากล  ให้ผู้เข้าอบรมได้เข้าใจถึงขั้นตอนการคำนวณและความหมายที่ถูกต้องของ MU เพื่อการนำไปใช้วัด ทดสอบ สอบเทียบ และลดความเสี่ยงในการตัดสินคุณภาพสินค้า

วัตถุประสงค์ 

  1. รู้จัก Measurement Uncertainty
  2. เข้าใจรากเหง้าที่มาของ Measurement Uncertainty
  3. เข้าใจหลักการและขั้นตอนการคำนวณ Measurement Uncertainty ตามแนวทางสากล
  4. สามารถนำ Measurement Uncertainty ไปใช้ตัดสินคุณภาพสินค้าได้อย่างถูกต้อง

เนื้อหาการบรรยาย

–   Measurement Overview
–   ผลการวัด Point estimation กับ Interval estimation
–   ความหมายทางมาตรวิทยาของ Measurement Uncertainty(MU)
–   คำนิยามที่ควรทราบ
–   มาตรฐานสากล ISO/IEC Guide 98-3 และมาตรฐานอื่นๆที่นิยมใช้เพื่อการคำนวณ MU
–  การคำนวณ Type A Standard uncertainty โดยวิธีสถิติ
–  การคำนวณ Type B Standard uncertainty โดยวิธีอื่น
–  การคำนวณ Combined standard uncertainty
–   t-distribution, Level of confidence และ coverage factor
–  การคำนวณ Expanded uncertainty
–   ตัวอย่างการคำนวณ
–   การประยุกต์ใช้ MU  ประกอบการวัด

 

หากต้องการสอบถามรายละเอียดเพิ่มเติม กรุณาติดต่อเจ้าหน้าที่ 02-578-0353 หรือส่งอีเมลมาที่ info@cal-laboratory.com

การจัดทำเอกสารเพื่อจัดการระบบคุณภาพตาม ISO 9001:2015

มาตรฐาน ISO 9001 เป็นมาตรฐานสำหรับการจัดการระบบคุณภาพ(Quality Management System) ที่ได้รับการยอมรับใช้แพร่หลายและมีการปรับปรุงเนื้อหามาเป็นระยะๆโดยฉบับปัจจุบัน คือ ISO 9001:2015 ซึ่งองค์กร ISO แถลงว่าได้มีการเน้นใช้หลักการของ  Process Approach และ การกำหนดให้ใช้พื้นฐานการคิดแบบ Risk-based thinking ประกอบเป็นข้อบังคับต่างๆจำนวน 10 หมวด ทั้งนี้การนำข้อกำหนด ISO 9001:2015 ไปประยุกต์ใช้เพื่อประโยชน์ในการจัดการระบบคุณภาพที่หน้างานต้องมีกรอบการปฏิบัติงานที่ถูกต้องสมบูรณ์เพื่อความสะดวกในการเชื่อมโยงข้อกำหนดไปสู่การปฏิบัติที่หน้างาน

กรอบงานที่สำคัญอย่างหนึ่งของการนำ ISO 9001:2015 ไปใช้ประโยชน์คือการมีระบบเอกสารที่รองรับระบบจัดการต่างๆอย่างเหมาะสมซึ่งในหลักสูตรนี้จะกล่าวถึงระบบเอกสารทั้งหมดที่นิยมใช้ในการจัดทำมาตรฐาน ISO 9001 รวมถึงเอกสารกระบวนงานสำคัญ อาทิ การตรวจติดตามภายใน และ การจัดการความเสี่ยง

วัตถุประสงค์ 

  1. เข้าใจถึงภาพรวมข้อกำหนดมาตรฐาน ISO 9001:2015
  2. เข้าใจถึงกรอบงานในการจัดทำระบบจัดการคุณภาพ ISO 9001
  3. เข้าใจถึงระบบเอกสารที่นิยมใช้เป็นเครื่องมือในการบริหารจัดการระบบคุณภาพ
  4. สามารถจัดทำระบบเอกสารอย่างเหมาะสมตามระบบจัดการคุณภาพ ISO 9001 พร้อมตัวอย่างเอกสารที่สามารถนำไปเป็นต้นแบบในการปรับปรุงพัฒนาใช้งานต่อไป

เนื้อหาการบรรยาย

– ภาพรวมข้อกำหนดมาตรฐาน ISO 9001:2015
– กรอบงานในการจัดทำระบบจัดการคุณภาพ ISO 9001
– คำนิยามที่เกี่ยวข้อง
– รู้จักมาตรฐาน ISO/TR 10013 ประกอบการจัดทำระบบเอกสาร ISO 9001
– ขยายความมาตรฐาน ISO 9001:2015 ข้อ 4 และข้อ 7.5
– การจัดทำเอกสารคู่มือคุณภาพ
– การจัดทำเอกสารขั้นตอนการปฏิบัติงาน
– การจัดทำเอกสารคำแนะนำงาน
– เอกสารกระบวนงานสำคัญที่ควรทราบ อาทิ การตรวจติดตามภายใน และ การจัดการความเสี่ยง

 

หากต้องการสอบถามรายละเอียดเพิ่มเติม กรุณาติดต่อเจ้าหน้าที่ 02-578-0353 หรือส่งอีเมลมาที่ info@cal-laboratory.com

การจัดระบบควบคุมเครื่องมือวัดตามข้อกำหนด ISO 9001:2015

การจัดการระบบคุณภาพตามมาตรฐาน ISO 9001:2015 นั้นต้องดำเนินการตามข้อบังคับครบทุกหมวด ซึ่งในจำนวนข้อบังคับทั้งหมดนี้มาตรฐาน ISO 9001:2015 ได้กำหนดให้องค์กรต้องจัดการทรัพยากรเครื่องวัดในหมวดข้อบังคับที่ 7.1.5 โดยกำหนดเฉพาะเป้าหมายการจัดการเครื่องวัดไว้โดยไม่ระบุรายละเอียดเชิงปฏิบัติ ดังนั้นจึงเป็นหน้าที่ขององค์กรที่ต้องจัดทำรายละเอียดการควบคุมเครื่องวัดขึ้นเองให้สอดคล้องกับเนื้อหาทางมาตรวิทยาและสอดคล้องกับระบบงานของ ISO 9001 ปัญหาคือองค์กรจะต้องปฏิบัติงานในรายละเอียดการควบคุมเครื่องวัดอย่างไรจึงจะเป็นไปตามข้อกำหนด

หลักสูตรนี้จะอธิบายและขยายความข้อกำหนดเครื่องวัดดังกล่าวในรายละเอียดทางมาตรวิทยารวมทั้งแสดงตัวอย่างเอกสารการจัดการเครื่องวัดเพื่อให้ผู้เข้าอบรมเข้าใจและสามารถปฏิบัติได้ตามข้อกำหนดของมาตรฐาน ISO 9001:2015

วัตถุประสงค์

  1. เข้าใจถึงความหมายของการวัด(Measurement)
  2. เข้าใจถึงข้อกำหนดมาตรฐาน ISO 9001:2015 ข้อ 1.5 ซึ่งเกี่ยวกับการควบคุมเครื่องวัด
  3. สามารถใช้เครื่องวัดอย่างถูกต้องตามหลักเกณฑ์และข้อกำหนดของมาตรฐาน
  4. สามารถจัดทำเอกสาร Procedure และ Work Instruction ระบบจัดการเครื่องวัดได้

เนื้อหาการบรรยาย

–  รู้จัก Measurement อย่างถูกต้อง, โครงสร้างและองค์ประกอบของระบบวัด
–  คำนิยามที่ควรทราบ
– ข้อกำหนด ISO 9001:2015 ข้อ 7.1.5 ซึ่งเกี่ยวกับการจัดการเครื่องวัด
– การเลือกเครื่องวัดอย่างเหมาะสม
– รู้จัก Measurement Uncertainty
– รู้จัก Test Uncertainty Ratio(TUR) ประกอบการวัด
– กระบวนการและการจัดทำเอกสาร Procedure, Work Instruction เพื่อควบคุมเครื่องวัดและการวัด
– การเก็บบันทึกเครื่องวัดและผลสอบเทียบเครื่องวัด
– การจัดให้มีความสอบกลับได้ในผลวัด(Measurement Traceability)
– การสอบเทียบและทวนสอบเครื่องวัด
–  การตรวจติดตามเพื่อจัดการเครื่องวัดอย่างต่อเนื่อง
– กิจกรรมการเริ่มระบบควบคุมเครื่องวัดสำหรับผู้เริ่มต้นใหม่

 

หากต้องการสอบถามรายละเอียดเพิ่มเติม กรุณาติดต่อเจ้าหน้าที่ 02-578-0353 หรือส่งอีเมลมาที่ info@cal-laboratory.com

การจัดระบบสอบเทียบเครื่องวัดตาม ISO 9001 สำหรับอุตสาหกรรม

การสอบเทียบเครื่องวัดเป็นกิจกรรมที่มีความสำคัญสำหรับการควบคุมและพัฒนาคุณภาพสินค้า ทั้งนี้มาตรฐานการจัดการคุณภาพ ISO 9001 กำหนดให้เครื่องวัดที่มีผลต่อคุณภาพสินค้าต้องได้รับการสอบเทียบโดยไม่แจงรายละเอียดการสอบเทียบเครื่องวัดว่าให้ดำเนินการอย่างไร สิ่งที่ภาคอุตสาหกรรมและการบริการต้องดำเนินการเองคือจัดระบบสอบเทียบเครื่องวัดให้มีประโยชน์สูงสุดต่อองค์กรและลดความเสี่ยงจากการวัดผิดให้น้อยสุดซึ่งหลักสูตรนี้จะช่วยให้บุคลากรที่รับผิดชอบการสอบเทียบเครื่องวัดสามารถพัฒนางานต่อไปได้ โดยหลักสูตรกล่าวถึง  ความสำคัญและความหมายของการสอบเทียบเครื่องวัด, การทวนสอบเครื่องวัด, การประเมินผลกระทบจากการสอบเทียบเครื่องวัดที่ต่อเนื่องกับงาน, การกำหนดช่วงเวลาสอบเทียบเครื่องวัด และ การพัฒนาระบบสอบเทียบเครื่องวัดเพื่อลดความเสี่ยงจากการวัดผิด

วัตถุประสงค์

  1. เข้าใจความสำคัญและความหมายของการสอบเทียบเครื่องวัด
  2. สามารถทวนสอบ (Verification) ผลสอบเทียบเครื่องวัดอย่างสอดคล้องกับเกณฑ์กำหนด
  3. สามารถประเมินผลกระทบจากการสอบเทียบเครื่องวัดที่ต่อเนื่องกับงาน
  4. สามารถพัฒนาระบบสอบเทียบเครื่องวัดเพื่อลดความเสี่ยงจากการวัดผิด

เนื้อหาการบรรยาย

–   ความหมายและความสำคัญของการสอบเทียบ
–   คำนิยามที่เกี่ยวข้อง
–   รู้จัก Measurement Uncertainty ประกอบการสอบเทียบ
–   หลักการและการเตรียมการเพื่อสอบเทียบเครื่องวัด
–   รู้จัก Test Uncertainty Ratio ประกอบการสอบเทียบและการวัด
–   การทวนสอบเครื่องวัดจากผลสอบเทียบ
–   Consumer risk(CR) และ Producer risk(PR)
–   การใช้ผลสอบเทียบประกอบการตัดสินคุณภาพสินค้าเพื่อลดความเสี่ยงในการวัดผิด
–  การสอบเทียบเพื่อให้มีความสอบกลับได้ของผลวัด

 

หากต้องการสอบถามรายละเอียดเพิ่มเติม กรุณาติดต่อเจ้าหน้าที่ 02-578-0353 หรือส่งอีเมลมาที่ info@cal-laboratory.com

การอ่านและใช้ประโยชน์ผลสอบเทียบเครื่องวัดสำหรับอุตสาหกรรม

การสอบเทียบเป็นกิจกรรมพื้นฐานในการยืนยันเครื่องวัด(Metrological Confirmation) ที่มีความสำคัญต่อความถูกต้องของการวัดงานเพราะการวัดผิดเป็นองค์ประกอบที่มีผลโดยตรงต่อการตัดสินคุณภาพสินค้าโดยมาตรฐานสากลหลายเล่ม เช่น มาตรฐาน ISO 9001, ISO/IEC 17025 เป็นต้น กำหนดไว้ให้ผู้รับผิดชอบในระบบการวัดต้องทำการสอบเทียบเครื่องวัด  แต่เนื่องจากการสอบเทียบและผลสอบเทียบมีรายละเอียดทางมาตรวิทยาที่ต้องทำความเข้าใจและต้องปฏิบัติอย่างถูกต้องรวมทั้งการนำผลการสอบเทียบไปใช้ประโยชน์อย่างคุ้มค่าต่อไปด้วย  เช่น การทวนสอบเครื่องวัดตามเกณฑ์คุณภาพสินค้า, การประเมิน drift และระยะเวลาสอบเทียบ(Calibration interval)อย่างถูกต้อง เป็นต้น  ดังนั้นเป้าหมายของการอบรมนี้มุ่งหมายให้ผู้เข้าอบรมเข้าใจถึงการอ่านและใช้ประโยชน์ผลสอบเทียบเครื่องวัดได้อย่างเป็นประโยชน์ต่อธุรกิจ

วัตถุประสงค์ 

  1. ตระหนักถึงความสำคัญของการสอบเทียบเครื่องวัดที่มีผลต่อธุรกิจ
  2. เข้าใจข้อกำหนดการสอบเทียบเครื่องวัดตามมาตรฐานสากล
  3. เข้าใจถึงการนำผลการสอบเทียบไปใช้ประโยชน์ต่อเนื่องในประเด็นสำคัญ
  4. สามารถจัดการกระบวนการสอบเทียบอย่างถูกต้อง

เนื้อหาการบรรยาย

–  ระบบโครงสร้าง และองค์ประกอบการวัด
–  ความสำคัญและผลกระทบของการสอบเทียบเครื่องวัดต่อคุณภาพสินค้า
–  ความหมายของการสอบเทียบ ทวนสอบ
–  ข้อกำหนดการสอบเทียบ ทวนสอบตามมาตรฐานสากล ISO 9001, ISO/IEC 17025
–  คำนิยามที่เกี่ยวข้อง
–  รายงานผลสอบเทียบที่ถูกต้องตามข้อกำหนดมาตรฐาน 17025
–  Traceability กับ ผลสอบเทียบ
–  ขยายผลข้อมูลรายงานผลสอบเทียบที่สำคัญ
–  การใช้ผลสอบเทียบเพื่อทวนสอบเครื่องวัดตามเกณฑ์ของงาน
–  การใช้ผลสอบเทียบเพื่อการประเมินMeasurement Uncertainty ของการวัด
–  Procedure สำหรับการสอบเทียบและทวนสอบ
–  Good practice สำหรับเครื่องวัดที่สอบเทียบแล้ว

 

หากต้องการสอบถามรายละเอียดเพิ่มเติม กรุณาติดต่อเจ้าหน้าที่ 02-578-0353 หรือส่งอีเมลมาที่ info@cal-laboratory.com

Exit mobile version