Temperature & Humidity
ห้องปฏิบัติการอุณหภูมิและความชื้น
Temperature & Humidity Calibration Service
Our Temperature and Humidity Laboratory provides calibration services for a wide range of temperature and humidity measuring instruments, with temperature calibration capabilities from -35 °C to 1,200 °C.
The laboratory is equipped with high-accuracy reference standards and calibration equipment, including ASL Standard Platinum Resistance Thermometers (SPRT), ASL Platinum Resistance Thermometers (PRT), ASL Precision Digital Thermometers, non-contact thermometers, Standard Type S Thermocouple Probes, Water Triple Point Cells, Calibration Liquid Baths, Dry Block Calibrators, Data Loggers, and Temperature & Humidity Chambers.
These reference standards and calibration systems are used to calibrate temperature measuring instruments, including indicators, sensors, thermometers, probes, data loggers, and temperature & humidity meters / thermo-hygrometers.
Calibration is performed using comparison calibration methods with reference standards and simulation methods for compatible instruments.
Accredited calibration services are available for applicable instruments and ranges within our approved ISO/IEC 17025 scope of accreditation.
| Equipment’s Standard | Brand | Model | Capability |
|---|---|---|---|
| 1. Standard Platinum Resistance Thermometer (SPRT) | Tinsley | 51875A | (-189) – 660 °C |
| 2. Platinum Resistance Thermometer (PRT) | Wika | CTP5000-652-D | (-70) – 650 °C |
| 3. Infrared Thermometer Calibrator | Wahl | CBB14AC-2 | 5 – 600 °C |
| 4. Standard Thermocouple Probe Type S | NIMT | Type S | 300 – 1300 °C |
| 5. Calibration Liquid Bath | Kambic | OB-22/2 ULT | (-90) – 250 °C |
| 6. Dry Block Calibrator | Presys | – | (-45) – 1200 °C |
| 7. Temperature&Humidity Chamber | PGC | – | 7 – 85 °C |
| 8. Chilled Mirror Dew Point Hygrometer / Dew Master | Edgetech | – | (-40) – 60 °C |
| 9. Tube Furnace | Elite TSH | – | 400 – 1100 °C |
| 10. Mini-Salt Bath Temperature Calibration | EDL | – | 200 – 500 °C |
| 11. Triple Point Water Cell | – | – |
(-70) – 250 °C
Thermocouple Type R: 0 – 1200 °C
Thermocouple Type S: 0 – 1200 °C
Thermocouple Type K: (-40) – 1200 °C
Thermocouple Type N: (-40) – 1200 °C
Thermocouple Type J: (-40) – 1200 °C
Thermocouple Type E: (-40) – 1000 °C
Thermocouple Type T: (-40) – 400 °C
(-30) – 250 °C
50 – 450 °C
Thermistor: (-80) – 250 °C
PRT: (-80) – 450 °C
Thermocouple Type T: (-80) – 400 °C
Thermocouple Type E: (-80) – 900 °C
Thermocouple Types K, N, J: (-80) – 1200 °C
Thermocouple Type R, S: 0 – 1200 °C
Thermocouple Type B: 600 – 1200 °C
Temperature: 15 – 45 °C
Humidity@25 °C: 30 – 90 %RH
Humidity@20 °C: 35 – 90 %RH
(-70) – 250 °C
(-40) – 1200 °C
Temperature: 15 – 45 °C
Humidity@25 °C: 30 – 90 %RH
Humidity@20 °C: 35 – 90 %RH
(-70) – 250 °C
(-70) – 250 °C (Type E, K, N, T, J, S, R)
Type E, K, N, J, T, S, R, B
RTD (100Ω PT(385) 4, 3, 2 wire): (-200) – 800 °C
Thermocouple Type R: 0 – 1700 °C
Thermocouple Type S: 0 – 1700 °C
Thermocouple Type K: (-100) – 1300 °C
Thermocouple Type J: (-100) – 1200 °C
Thermocouple Type E: (-100) – 1000 °C
Thermocouple Type T: (-150) – 400 °C
Thermocouple Type R: 0 – 1200 °C
Thermocouple Type S: 0 – 1200 °C
Thermocouple Type K: (-70) – 1200 °C
Thermocouple Type N: (-70) – 1200 °C
Thermocouple Type J: (-70) – 1200 °C
Thermocouple Type E: (-70) – 1000 °C
Thermocouple Type T: (-70) – 400 °C
200 – 1200 °C
105 – 135 °C
(-70) – 0 °C
5 – 70 °C
50 – 250 °C
50 – 250 °C
About Us
Company History
Services
Pressure & Vacuum
Dimension
Torque & Force
Electrical
Mass & Balance
Glassware & Chemical
Medical
Flow
Trainings
Promotion
Pressure & Vacuum
Dimension
Temperature & Humidity
Torque & Force
Electrical
Mass & Balance
Glassware & Chemical
Others
Articles
Videos
News