Showing 21–40 of 67 results

Electrical

ห้องปฏิบัติการไฟฟ้า

Electrical, Time & Frequency and Vibration Calibration Service

Our Electrical Laboratory provides calibration services covering a wide range of electrical, vibration, and light measurement functions.

Calibration services are performed under our ISO/IEC 17025 quality system. Accredited calibration is available for applicable instruments and measurement ranges within our approved scope of accreditation.

Electrical Calibration Laboratory

The laboratory is equipped with reference standards and calibration equipment, including a FLUKE 5500A Multi-Product Calibrator, Transconductance Amplifier, Picoampere Source, Intelligent Counter, High Voltage Probe, 8.5 Digit Multimeter, Standard Inductors, Standard Resistors, and Standard Capacitors.

These reference standards and calibration systems are used for the calibration of AC/DC voltage, current, electrical power, resistance, capacitance, inductance, and other electrical measuring functions.

Time and Frequency Laboratory

Our Time and Frequency Laboratory is equipped with an HP Quartz Frequency Standard, Universal Frequency Counter, Signal Generator, and Oscilloscope Calibrator.

These standards are used for the calibration of oscilloscopes, frequency counters, stopwatches, and other time and frequency measuring instruments.

Vibration Laboratory

Our Vibration Laboratory is equipped with reference standards and calibration equipment, including Brüel & Kjær Standard Vibration Pickup and Charge Amplifier, HP Universal Counter, HP Digital Multimeter, and Brüel & Kjær Accelerometers.

These systems are used for the calibration of vibration measuring instruments and vibration calibrators over a range from 0 to 70 Gp, using comparison calibration and simulation calibration methods.

We provide calibration services for vibration indicators and other vibration measuring instruments used in industrial, manufacturing, testing, and quality control applications.

EQUIPMENT'S STANDARD
Equipment’s Standard Brand Model Capability
1. Illuminance Calibrator Benthem Optimar 100 0 – 20000 Lux
2. DC Reference Standard FLUKE 732A 1 V, 1.018 V, 10 V
3. Digital Multimeter HP/Agilent 3458A 1 mV – 1000 V
4. Resistance Standard CAEAAHO 0.001 W, 0.01 W, 0.1 W, 1 W, 10 W,
100 W, 1000 W, 10000 W, 100000 W, 10 MW
5. Multi Product Calibrator Transmille 9041 A, 4010
6. Multi Product Calibrator FLUKE 5500A
7. Oscilloscope Calibrator Tektronix
8. Inductor General Radio Co.
9. Reference Standard Accelerometer Bruel & Kjear 8305
10. Vibration Exciter Bruel & Kjear 4809
11. Conditioning Amplifier 2650

No.
Instrument Name
Capability
21
Stroboscope

1 – 99999 rpm

22
Tachometer

Contact Type: 1 – 99999 rpm
Non Contact Type: 1 – 99999 rpm

23
Non Contract Speedo Meter

0 – 300 km/hr

24
Data Logger

DCV (Input ACV): 0 – 1000 V
DCA (Input ACA): 0 – 30 A
Resistance: 0 – 400 Ω
Temp.: (-200) – 1300 °C

25
Clamp On Meter

Resistance: 0 – 330 MΩ
ACV, DCV: Up to 1000 V
ACA, DCA: Up to 1500 A

26
Clamp On Leak Tester

Resistance: 0 – 330 mΩ
ACV, DCV: Up to 1000 V
ACA, DCA: Up to 1500 A

27
Clamp On Power Tester

Resistance: 0 – 1500 kΩ
ACV, DCV: Up to 1000 V
ACA, DCA: Up to 1500 A

28
Power Analyzer

ACV, DCV: 0 – 1000 V
ACA, DCA: 0 – 11 A

29
Power Meter

ACV, DCV: 0 – 1000 V
ACA, DCA: 0 – 30 A
Power (AC, DC): 0 – 30 kW
P.F.: 0 – 1

30
Watt Meter

Power (AC, DC): 0 – 30 kW
P.F.: 0 – 1

31
Analog Watt Meter (Single Phase)

Power (AC, DC): 0 – 30 kW

32
Digital Watt Meter (Three Phase)

ACV, DCV: 0.5 – 560 V
ACA, DCA: 1 mA – 120 A
Power (AC, DC): 0.5 mW – 67.2 kW
P.F.: 0 – 1

33
Analog Watt Meter (Three Phase)

Power (AC, DC): 200 W – 1000 kW
ACA, DCA: 1 mA – 30 mA
Power (AC, DC): 0 – 67 kW

34
Analog Multimeter

Resistance: 0 – 330 mΩ
ACV, DCV: 0 – 1000 V
ACA, DCA: 0 – 30 A
Power (AC, DC): 0 – 11000 W
Frequency: 10 Hz – 500 kHz
Capacitance: 330 pF – 1.1 mF

35
Digital Multimeter

Resistance: 0 – 330 mΩ
ACV, DCV: 0 – 1000 V
ACA, DCA: 0 – 11 A
Power (AC, DC): 0 – 11000 W
Frequency: 0.01 Hz – 2 MHz

36
Phase Detector

Phase 1, 2, 3 (RST) 0 – 500 V

37
Earth Tester

0 – 100 kΩ

38
Current Transformer

0 – 30 A

39
Analog Panel Meter

Resistance: 0 – 330 mΩ
ACV, DCV: 0 – 1000 V
ACA, DCA: 0 – 30 A
Power (AC, DC): 0 – 11000 W
Frequency: 10 Hz – 500 kHz
Capacitance: 330 pF – 1.1 mF

40
Counter

0 – 10 MHz