Electrical
ห้องปฏิบัติการไฟฟ้า
Electrical Calibration Laboratory
The laboratory is equipped with reference standards and calibration equipment, including a FLUKE 5500A Multi-Product Calibrator, Transconductance Amplifier, Picoampere Source, Intelligent Counter, High Voltage Probe, 8.5 Digit Multimeter, Standard Inductors, Standard Resistors, and Standard Capacitors.
These reference standards and calibration systems are used for the calibration of AC/DC voltage, current, electrical power, resistance, capacitance, inductance, and other electrical measuring functions.
Time and Frequency Laboratory
Our Time and Frequency Laboratory is equipped with an HP Quartz Frequency Standard, Universal Frequency Counter, Signal Generator, and Oscilloscope Calibrator.
These standards are used for the calibration of oscilloscopes, frequency counters, stopwatches, and other time and frequency measuring instruments.
Vibration Laboratory
Our Vibration Laboratory is equipped with reference standards and calibration equipment, including Brüel & Kjær Standard Vibration Pickup and Charge Amplifier, HP Universal Counter, HP Digital Multimeter, and Brüel & Kjær Accelerometers.
These systems are used for the calibration of vibration measuring instruments and vibration calibrators over a range from 0 to 70 Gp, using comparison calibration and simulation calibration methods.
We provide calibration services for vibration indicators and other vibration measuring instruments used in industrial, manufacturing, testing, and quality control applications.
| Equipment’s Standard | Brand | Model | Capability |
|---|---|---|---|
| 1. Illuminance Calibrator | Benthem | Optimar 100 | 0 – 20000 Lux |
| 2. DC Reference Standard | FLUKE | 732A | 1 V, 1.018 V, 10 V |
| 3. Digital Multimeter | HP/Agilent | 3458A | 1 mV – 1000 V |
| 4. Resistance Standard | CAEAAHO | – | 0.001 W, 0.01 W, 0.1 W, 1 W, 10 W, 100 W, 1000 W, 10000 W, 100000 W, 10 MW |
| 5. Multi Product Calibrator | Transmille | 9041 A, 4010 | |
| 6. Multi Product Calibrator | FLUKE | 5500A | |
| 7. Oscilloscope Calibrator | Tektronix | – | |
| 8. Inductor | General Radio Co. | – | |
| 9. Reference Standard Accelerometer | Bruel & Kjear | 8305 | |
| 10. Vibration Exciter | Bruel & Kjear | 4809 | |
| 11. Conditioning Amplifier | – | 2650 |
512 – 32768 Hz
1 s – 24 hr
0.2 mV – 30 V
5 ns – 200 ms
225 MHz
Displacement (@80Hz, 160 Hz): >0 – 100 µm
Acceleration (@50 Hz – 5 kHz): >0 – 100 m/s²
Velocity (@50 Hz – 5 kHz): >0 – 100 mm/s
Frequency: 50 Hz – 1 kHz
Acceleration (@50 Hz – 5 kHz): >0 – 100 m/s²
Displacement (@80Hz, 160 Hz): >0 – 100 µm
Acceleration (@50 Hz – 5 kHz): >0 – 100 m/s²
Velocity (@50 Hz – 5 kHz): >0 – 100 mm/s
Frequency (@10 m/s²): 50 Hz – 1 kHz
SIM: Up to 1000 pA
Temp. (Source & Measure):
Type J, K, T,E, R, S, B, C, G, D, U, L
PT100, Ni100 Ω, Ni120 Ω, Ω, mV, mA
Resistance: 0 – 330 MΩ
DCV: 0 – 1000 V
ACV: 10 mV – 1000 V
DCA: 0 – 30 A
ACA: 10 µA – 30 A
Frequency: 10 Hz – 10 kHz
Temp. (Source & Measure):
Type J, K, T,E, R, S, B, C, G, D, U, L
Resistance: 0 – 330 MΩ
DCV: 0 – 1000 V
ACV: 10 mV – 1000 V
DCA: 0 – 30 A
ACA: 10 µA – 30 A
Frequency: 0 – 10 kHz
Temp. (Source & Measure):
Type J, K, T,E, R, S, B, C, G, D, U, L
Inductance: 100 µH – 1 H
Capacitance: 100 pF – 10 µF
Resistance: 1 Ω – 10 MΩ
Inductance: 100 µH – 1 H
Capacitance: 1 pF – 1 F
Resistance: 1 mΩ – 10 GΩ
0 – 100 %
100 – 13000 prm
1 kΩ – 10 TΩ
0 – 50 kA
0 – 50 kA
1 – 20000 Lux
1 – 20000 cd/m²
About Us
Company History
Services
Pressure & Vacuum
Dimension
Temperature & Humidity
Torque & Force
Mass & Balance
Glassware & Chemical